Control Supply
|
Wiring terminals 11-12 (Single-resistor Intellicrane Roter Controller)
|
AC 220V(-35%~+10%),50/60Hz
|
Wiring terminals B1-B2 (Multi-resistor Intellicrane Roter Controller)
|
||
Control power supply current (Single-resistor Intellicrane Roter Controller)
|
Max. 0.12A
|
|
Control power supply current (Multi-resistor Intellicrane Roter Controller)
|
Max. 0.3A
|
|
Current capacity
|
30A、63A、110A、160A、200A、300A、400A、500A、630A、800A
|
|
Power circuit input voltage
|
IRC — — R1 —
|
Rotor voltage ≤ AC500V
|
IRC — — R2 —
|
AC500V < Rotor voltage ≤ AC690V
|
|
IRC — — R3 —
|
AC690V < Rotor voltage ≤ AC1000V
|
|
Digital signal input control voltage
|
Provided internally by IRC1
|
DC 24V,Once input voltage ≤ 8mA
|
"Off" signal range
|
-5V~1V
|
|
"On" signal range
|
19V~24V
|
|
Switching frequency
|
≤ 2Hz
|
|
Relay Output Contact Performance
|
On-Off Status Relays
|
AC 250V/2A Mechanical Life 1x10⁷ times
|
Fault Status Relays
|
AC 250V/2A Mechanical Life 1x10⁷ times
|
|
Smart Controller Performance
|
Response time
|
≤ 1ms+ half power supply cycle
|
Operating system
|
Jc ≤ 60%
|
|
Protection Function
|
Power unit over-temperature alarm
|
|
Thyristor conduction fault alarm
|
||
Thyristor cut-off fault alarm
|
||
Ambient operating temperature
|
-25℃~+120℃ (Lower capacity over 60℃)
|
|
Storage temperature
|
-40℃~+120℃
|
|
Relative humidity
|
<90%, no condensation allowed
|
|
Altitude
|
Max. 2000m at continuous rated current.
Over 2000m reducing by 1% for each 100m, and the maximum altitude is 3000m. |
|
Power loss
|
Approx. 3.8W/A actual motor rotor operating current at 60% connection duration
|
|
Waterproof
|
IP20
|