Control Supply
|
Wiring terminals 21-22
|
AC 220V(-35%~+10%),50/60Hz
|
200A and below 200A power supply current
|
Max. 0.12A
|
|
300A and over 300A power supply current
|
Max. 0.18A
|
|
Current capacity
|
30A、63A、110A、160A、200A、300A、400A、500A、630A、800A
|
|
Power circuit input voltage
|
IPC1 — — 380
|
Rotor voltage ≤ AC500V
|
IPC1 — — 525
|
AC500V < Rotor voltage ≤ AC690V
|
|
IPC1 — — 690
|
AC690V < Rotor voltage ≤ AC1000V
|
|
Digital signal input control voltage
|
Provided internally by IPC1
|
DC 24V,Current input ≤ 8mA
|
"Off" signal range
|
0V~1V
|
|
"On" signal range
|
19V~24V
|
|
Switching frequency
|
≤ 2Hz
|
|
Output Relays
|
Abnormal Status Relays
|
AC 250V/2A Mechanical Life 1x10⁷ times
|
Brake Control Relays
|
AC 250V/2A Mechanical Life 1x10⁷ times
|
|
On-Off Status Relays
|
AC 250V/2A Mechanical Life 1x10⁷ times
|
|
Fault Status Relays
|
AC 250V/2A Mechanical Life 1x10⁷ times
|
|
Working Performance
|
Response time
|
≤ 1 ms+ half power supply cycle
|
Operating system
|
Jc ≤ S3-60% (Reducing current capacity over 60% operation system)
|
|
Protection Function
|
Overcurrent protection
|
|
Insufficient current protection
|
||
Three-phase current unbalance or phase loss protection
|
||
Motor overheating protection
|
||
Fixed time overcurrent, instantaneous high current protection
|
||
Reverse time overcurrent protection
|
||
Power failure abnormal state protection
|
||
Ambient operating temperature
|
-25℃~+60℃ (Lower capacity over 60℃)
|
|
Storage temperature
|
-25℃~+120℃
|
|
Relative humidity
|
<90%RH, no condensation allowed
|
|
Altitude
|
Max. 2000m at continuous rated current.
Over 2000m reducing by 1% for each 100m, and the maximum altitude is 3000m. |
|
Power loss
|
Approximately 2W/A actual motor operating current at S3-60% connection duration
|
|
Waterproof
|
IP20
|
WeChat Official Account