Power input
|
Input voltage Uin
|
3-phase/AC220V (-15%~+10%)
3-phase/AC320V (-15%~+ 10%) |
Input voltage frequency
|
50HZ (±2HZ)
|
|
Output to electromagnetic disk
|
Output voltage Uout
|
0~1.35Uin
|
Voltage resolution
|
5%Uout
|
|
Control Features
|
Control method
|
Three-phase thyristor fully controlled rectifier bridge application function
|
Application function
|
Constant voltage control
Constant current control Analog input control (0- 10VDC) |
|
Environmental conditions
|
Ambient temperature
|
-10°C (no frost) ~+60°C
|
Storage temperature
|
-40°C~+60°C
|
|
Relative humidity
|
< 95%, no condensation allowed
|
|
Altitude
|
Max. 1000m
Over 2000m reducing by 1% for each 100m |
|
Protective function
|
Low voltage protection
|
0.7Uin
|
Over temperature protection
|
> 100°C
|
|
Grid monitoring
|
Phase loss monitoring
Phase sequence error |
|
Overcurrent protection
|
More than 2 times the setting value of parameter 3 for more than 1 second continuously
|
|
Waterproof
|
Control unit
|
IP51
|
Power unit
|
IP20
|